A fire extinguisher could save your life in an emergency. Whether you work in an office building, commercial, warehouse environment, or industrial site, or even for your home, having the right type of fire extinguisher in the right location is essential, that’s why we provide DCP Fire Extinguishers in Pakistan to save your life.DCP Mobile System Fire Extinguisher

DCP Fire Extinguisher is standing for Dry Chemicals Powder Fire Extinguisher. DCP Fire Extinguishers in Pakistan are the most widely used of all types of extinguishers.

DCP fire extinguisher is a dry chemical fire extinguisher and is very efficient firefighting equipment. It is a very versatile fire extinguisher that can extinguish different classes of fire (class A, B, E). A dry chemical fire extinguisher is most widely used for fire protection and very quickly knocks out the fire. It is also known as BE or ABE fire quencher. They are ideal to extinguish mixed fire risk environments. We can use it for the protection of fire that occurs by liquids, storage of liquid gases, and heating oils used for industry, garages, and workshops. We can recognize a dry chemical fire extinguisher by its white band around the cylinder.

DCP fire extinguisher is essential for every kind of building and because of this reason we cannot deny the importance of DCP fire extinguishers. This kind of fire extinguisher can save the assets of the company from fire damages. They can provide rescue services without the assistance of the fire brigades or emergency service providers.

This kind of fire extinguisher is highly effective and due to its versatile nature users can use it in various places like:DCP Mobile System Fire Extinguisher

Mechanical Rooms.
Chemical Storage area.
Commercial Kitchen.
Fire Rooms.
Computer rooms.

SPECIFICATIONS OF DCP FIRE EXTINGUISHER

The DCP fire extinguishers are available in different sizes such as 1 kg, 2 kg, 4 kg,6 kg,8 kg, and 12kg. The material of the cylinder is steel. The extinguishing agent is mono ammonium phosphate and ammonium sulfate powder and the discharge time of the agent is 13 seconds. DCP Mobile System Fire Extinguisher The classes of fire it can effectively extinguish include classes A, B, C, and E.

WHAT DOES DCP FIRE EXTINGUISHER CONTAIN?

The chemical inside the fire extinguisher is a mixture of mono ammonium phosphate and ammonium sulfate powder. The proportion of these two chemical powders is 40:60 or 60:40. The mixture when heated can melt and flow. When the melted mixture the cylinder over the fire it coats the flames and terminates the fire.

WORKING PRINCIPLE OF DCP FIRE EXTINGUISHER

The fire breaks out when all the three elements of the fire triangle (heat, oxygen, fuel) are present. For the successful suppression of fire, any one element of the fire triangle should be absent. The dry powder type extinguishers work by discharging a fine powder using pressurized gas to spray it from the storage cylinder on the fire so that fire can be extinguished. DCP fire extinguisher puts out the fire by coating the fuel with a layer of powder and in this way the powder creates a barrier between the fuel and oxygen. When the fire extinguisher sprays the powder over the fire, this powder cuts off the supply of oxygen and rapidly knocks out the fire. After extinguishing the fire, we can clean the residue with the help of a vacuum cleaner.DCP Mobile System Fire Extinguisher

WHAT CLASSES OF FIRE IT CAN EXTINGUISH?

DCP fire extinguishers are very reliable for extinguishing the following classes of fires:

CLASS A (ORDINARY COMBUSTIBLES):

Class A fire occurs due to material made of paper, wood, and textile. The fire extinguisher uses pressurized water, foam, and multipurpose dry chemical to extinguish the Class A fire.

CLASS B (FLAMMABLE LIQUIDS, GREASES, OR GASES):

The fire breaks out by liquids, greases, or gases such as petrol, diesel, or oil. Fire extinguisher uses Foam, carbon dioxide, dry chemical, and multipurpose dry chemical to extinguish Class B fire.

CLASS C (COMBUSTIBLE GASSES):

Fire is caused by combustible gasses like natural gas, LPG.

CLASS E (ENERGIZED ELECTRICAL EQUIPMENT):

Extinguish energized electrical equipment by using an extinguishing agent that is not capable of conducting electrical currents. Fire extinguishers used multipurpose dry chemicals, carbon dioxide, and dry chemicals to extinguish this type of fire.

TYPES OF DCP FIRE EXTINGUISHER

DCP Fire Extinguisher is further classified into two types based on classes of fire they extinguish and the chemical they used to extinguish the fire.DCP Mobile System Fire Extinguisher

ABE DRY CHEMICAL POWDER FIRE EXTINGUISHER: This is one of the commonly used types of DCP fire extinguishers. The name of ABE dry chemical powder is this because of the classes of fire it can extinguish effectively. It can extinguish Class A, Class B, and Class E fire. The cylinders contain mono ammonium phosphate which can melt and flow easily from the cylinder over the fire and extinguish the fire. They are useable in vehicles, home kitchens, workshops, homes, and offices, and so on.
BE DRY CHEMICAL POWDER FIRE EXTINGUISHER: This is another type of DCP fire extinguisher. Because of the classes of fire, it can trigger we call it BE dry chemical fire extinguisher The powder inside the container does not melt that is why it is ineffective against class A fires so it is BE dry chemical powder. Both types of DCP Fire extinguishers can suppress the fire caused by flammable gas, but the user has to evaluate the situation before using it. Because after extinguishing the gas can leak out again and can cause re-ignition.

INSTALLATION GUIDE

Before installing the fire extinguishers, it is important to ensure that the extinguishers user install them in the correct location, and are certified as proof of correct installation and sufficient provision against the fire safety risks.

LOCATION ADVICE:
Before installing the fire extinguisher, the first question is about the location for the installation of the fire extinguishers. The location and the distance for the installation of the fire extinguisher are based on the size of the area, the type of fire extinguishers, and the locations of potential hazards.
ADVICE FOR INSTALLATION HEIGHT: To prevent the fire extinguishers from damage or the easy access of the fire extinguishers user should install them on a cabinet or bracket with their carrying handles placed 3-1/2 to 5 feet so that it is easy for the user to use it. The fire extinguishers must be installed at a height that is equal to the average height of the human being.
ATTACHING TO THE WALL: The suppliers should supply fire extinguishers with all complete accessories like wall brackets to ensure the installation of extinguishers to the wall to protect the cylinders from damages. Like Fire, extinguishers are stored in a safe place so that they can be saved from damages.

FIRE EXTINGUISHER INSTRUCTION SIGNS & LABELS:

Fire safety devices or equipment are useless without easy-to-follow instructions and it is important to ensure that the instructional tags are attached to the fire extinguisher because the efficient results of the DCP extinguisher depend on the instructions. The instructional tags must include the necessary information about the fire extinguishers. The information that must be listed down on instruction is the type of extinguishing agent inside the extinguisher, Whether the extinguisher has an adequate charge and is ready for use etc. All the fire extinguishers are sealed with the lead using copper wire.

MONTHLY INSPECTION RECORD LABEL:

The monthly inspection record label must be tagged with a DCP fire extinguisher along with the expiry date. This tag has 12 boxes with the name of each month labeled on it. Monthly inspection of the fire extinguisher is the responsibility of the end-user because once the service providing company hands over the extinguisher to the user then they should pay attention to their maintenance.

FIRE EXTINGUISHER REFILLING:

DCP Fire extinguishers require refilling after year. For refiling the owner of the organization must contact any reputable and highly professional fire extinguisher providers. The owner must pay attention to its expiry dates because it is a very crucial element.

DCP Fire Extinguisher in Pakistan:

Dry chemical powder extinguishers are suitable for class A (combustible materials), class B (flammable or combustible liquids), and/or class C (electrical) fires or a combination of ABC class fires. All the extinguishers supplied conform to the minimum fire ratings as specified in SANS 1910:2009.

They are highly effective for electrical hazards. This multi-purpose extinguisher interferes with the combustion process and provides rapid-fire knockdown. They are ideal for mixed fire risk environments and especially suited for protection for liquids, storage of liquid gases, and heating oils used for industry, garages, and workshops.

Universal Fire Protection offers a wide range of fire extinguishers to suit specific firefighting applications, including Carbon Dioxide (CO2), Water, Foam & Wet chemicals, Dry Chemical Powder, and Mobile extinguishers products with quality service at your Door Step.
DCP FIRE EXTINGUISHER PRICES IN PAKISTAN

Universal Fire Protection provides all types of DCP (Dry Chemical Powder) Fire Extinguishers and at a very cheap price in Pakistan Karachi, Lahore, Islamabad, and Rawalpindi.

BUY DCP FIRE EXTINGUISHERS IN PAKISTAN

BEST SHOPS OF DCP FIRE EXTINGUISHERS IN PAKISTAN

Because Fire can be a big threat to the success and productivity of the company. Universal Fire Protection CO Pvt is here to serve you because we do care about your safety. We provide a complete range of fire extinguishers.No matter what is the type and size of your business in Pakistan, we are here to provide services according to your requirements.

We are a reliable fire safety products supplier like fire extinguishers, wheeled fire extinguishers, Halotron fire extinguishers, automatic extinguishers, and foam fire extinguishers, Chinese fire Extinguishers, water fire extinguishers, and CO2 fire extinguishers all across Lahore, Karachi, and Rawalpindi.

Purchase Best Quality DCP Fire extinguisher from Universal Fire Protection CO Pvt. Always feel free to contact us to get the quotation.
Dcp Fire extinguishers

DCP fire extinguishers are the most versatile among all types of fire extinguishers. It is a valuable fire fighting equipment used for suppressing the fire, because of its widespread uses. A dry chemical powder is used as a fire extinguishing agent in Dcp fire extinguisher. It is being used for extinguishing many classes of fire like A, B, C, E and F.

DCP Fire Extinguisher is designed from high quality material and made it highly effective and reliable. This device works great and gives you an immediate protection against fires. It offers fast action on ignition and provides a good burn time (3-6 minutes).
What is the dcp powder?

Dcp powder is a fire extinguishing agent, it is composed by mixing Ammonium Sulphate and mono Ammonium Phosphate, which is used inside the fire extinguishers for extinguishing class A, B, C, E and F fires.
DCP stands for?

DCP stands for dry chemical powder. It is used in fire extinguishers.
Where is dcp fire extinguishers used ?

DCP fire extinguishers can be used in kitchens, laboratories, industries, petrol pumps, server rooms, and the areas where machinery is placed.

Note: Not recommended for use on expensive and delicate equipment like computers, etc.

It can be recognized by the blue colored label on the cylinder on which powder is written.

Usage:It extinguishes fire on the organic materials, flammable liquids and flammable gases.

DCP fire extinguishing system is made up of advanced technology, which makes the product safer than others. Besides, they have fully equipped models of fire extinguishers with a different design and structure that work efficiently.

Size of DCP fire extinguishers:

The DCP fire extinguishers vary in size. They come in 1kg, 2kg, 4kg, 6kg, 8kg, 12kg. you can choose according to your needs.
Which chemical powder is used in the DCP fire extinguisher:

As the name indicates the DCP extinguisher is filled with a chemical that is used to extinguisher extinguishes the fire. Sodium bicarbonate and potassium bicarbonate are the chemicals, which are present in the cylinders of DCP extinguishers. These chemicals acts as a shield on the burning material and cut off the supply of oxygen. Since the oxygen gas is required for the fire to spread, but when the supply of oxygen is cut off the fire ultimately extinguishes.
What is the pressure of DCP fire extinguisher:

The pressure of the DCP fire extinguisher varies with the weight. If the weight of DCP fire extinguisher is 6 kgs the pressure on which it operates will be 15kgf/cm², and it will discharge the fire extinguishing agent in 20 seconds. Similarly, the working pressure of a DCP extinguisher will differ according to the weight of its cylinder.
What are DCP extinguishers used for:

The DCP fire extinguisher are used for extinguishing most classes of fire. Due to this reason DCP fire extinguishers are most commonly used among all types of fire extinguishers. It can be used to suppress the fire from smaller to larger scales, i.e, they can be used for extinguishing the small fires at home to the larger fires at the mining sites.

On which classes of fire the DCP fire extinguishers can be used for:

There are many classes of fire on which DCP extinguishers can be used to extinguish them. Those classes are mentioned below:

1- Class A fire: This fire includes the burning of paper textile and wood.

2- Class B fire: This fire took place due to burning of the combustible liquids like oil petrol and alcohol.

3- Class E fires: This fire is caught by the electrical equipment due to the electric spark.

4- Class F fire: This fire involves the burning of cooking oils and fats.

The DCP extinguisher is used for extinguishing most classes of fire. Due to this reason DCP fire extinguishers are most commonly used among all types of fire extinguishers. It can be used to suppress the fire from smaller to larger scales, i.e, it can be used for extinguishing the small fires at home to the larger fires at the mining sites.

On which classes of fire the DCP fire extinguishers can be used for:

There are many classes of fire on which DCP fire extinguisher can be used to extinguish them. Those classes are mentioned below:

1- Class A fire: This fire include the burning of paper textile and wood.

2- Class B fire: This fire took place due to burning of the combustible liquids like oil petrol and alcohol.

3- Class E fires: This fire is caught by the electrical equipment due to the electric spark.

4- Class F fire: This fire involves burning of cooking oils and fats. of fires.

DCP fire extinguisher is versatile enough to extinguish all these classes of fires.
DCP fire extinguisher cartridge type:

The DCP fire extinguisher cartridge type contains carbon dioxide as an expellant. The cartridge contains CO² which is sealed to prevent leakage. The cylinder is made up of steel which has a removable internal shell containing gas pores. Rubber rings and washer are used to protect the shell. There is a siphon tube installed in the DCP extinguisher cartridge type. At the of the siphon tube there is a nozzle, which has a rubber cap for it’s protection.
How to use DCP fire extinguisher:

It is important to know that how to use the DCP fire extinguisher, the principle of P.A.S.S to operate a DCP fire extinguisher.

P- Pull the Pin.

A- Aim the nozzle at the base of the fire.

S- Squeeze the handle.

S- Sweep the side to side.
How does a DCP fire extinguisher work:

DCP fire extinguisher extinguishes the fire by smut hearing effect. Chemical powder present in the cylinder of DCP extinguisher covers the fuel of fire and cuts off the supply of oxygen, in this way, the fire triangle breaks and the fire gets extinguished.
Advantages of DCP extinguisher:

There are many advantages of DCP extinguishers.

1- It has a wide application it can be used on many classes of fire.

2- The DCP extinguisher has a reasonable price therefore economical.

3- DCP extinguisher is available in many sizes.
Disadvantages of DCP extinguisher:

1- DCP extinguisher leaves are residue on the equipment and the other things, which becomes difficult to clean or even damages the equipment.

2- They cause irritation to the respiratory organs if inhaled.

Leave a Reply

Your email address will not be published.

Best Way Traders (Pvt.) Ltd.